On Load Tap Changer

Manufacturer of a wide range of products which include l type on load tap changer, i type on load tap changer, m type on load tap changer, v type on load tap changer, d type on load tap changer and dry type on load tap changer.

L Type On Load Tap Changer

Request Callback

Get Latest Price

PhaseThree Phase
TypeOn Load
Rated Voltage825 V
Frequency50 Hz
Power Rating200A
Voltage For Operational Equipment33 kV
Operating Positions Without Changeover Selector9 (Max)
Operating Positions With Changeover Selector17 (Max)
ModelL Type
MaterialSS
Key Features – L Type Tap Changer
  • Integrated drive mechanism offers compact design and efficient operation.

  • Capable of handling up to 500,000 operations, ensuring long-term reliability.

  • No barrier board or large sealing area required, minimizing leakage risks.

  • Slim structure eliminates the need for a conservator, reducing piping and installation costs.

  • Maintenance-free for up to 50,000 operations with no barrier board-related issues.

  • Quick inspection time – OLTC inspection can be completed within 30 minutes.

  • Current rating: 200 A.

  • Voltage levels: 11 kV, 22 kV, and 33 kV.

  • Vector compatibility: Supports both Y (star) and D (delta) configurations.

  • Basic Insulation Level (BIL): 80/250 kV/kVp.

  • Maximum rated step voltage: 825 V.

  • Operating positions: Up to 9 linear and 17 pre-selector positions.

I Type On Load Tap Changer

Request Callback

Get Latest Price

PhaseThree Phase
Current Rater200A
Step Voltage825 V
Power Capacity of Three Phase140 kVA
Voltage for Operational Equipment33 kV
Operation Position17 (Max)
MaterialSS
I Type On Load Tap Changer – Key Features
  • Designed for voltage range from 11 kV to 33 kV.

  • Supports up to 9 linear and 17 pre-selector tap positions.

  • Built for compact integration into distribution transformers.

  • Ensures efficient voltage regulation during live operations.

  • Features rugged construction for long-term reliability.

  • Suitable for both Y (star) and D (delta) vector group applications.

M Type On Load Tap Changer

Request Callback

Get Latest Price

PhaseThree Phase
Max Rated600A (Three Phase)
Max Voltage3,300V
Capacity Single Phase3,500 kVA
Capacity Three Phase1,500 kVA
Operational Equipment Um300 kV
Operating Positions Without Change Over Selector22 (Max)
Operating Positions with Change Over Selector35 (Max)
Key Features
  • The M Type Tap Changer is designed for use in transformers rated up to 765 kV.

  • Three-pole models are available with current ratings of 350 A, 500 A, and 600 A, suitable for Y-connected windings.

  • Single-pole models are available with 350 A, 500 A, 600 A, 800 A, 1200 A, 1500 A, and 1800 A ratings, ideal for auto-connected or single-phase transformers.

  • Special designs are offered for 700 A (3-phase) and 2100 A or 2400 A (single-phase) applications.

  • Tap changer configurations are available with 9, 11, 13, 15, or 17 tap positions.

  • The system supports both star (Y) and delta (D) grounding insulation, with independently selectable tap selector sizes.

  • It features a high-speed transition resistor-type diverter switch, ensuring arc extinction at the first current zero.

  • The diverter uses sharp-action mechanics, supported by energy accumulators mounted directly on the switch.

  • For current ratings ≥ 500 A, arcing contacts are made from tungsten-copper alloy to ensure durability.

  • The design ensures long operational life, minimal maintenance, and low thermal stress on transition resistors.

  • The tap changer has a compact structure, enabling effective cooling and high short-circuit withstandability.

  • Radial dimensions and impulse voltage performance are optimized using specially shaped parts to manage voltage stress.

  • The change-over selector is seamlessly integrated within the fine selector contact circle for efficient performance.

  • Optional special contacts are available for use with alternative insulating liquids.

  • The unit is suitable for bell-type tank installations and includes a built-in mechanism for potential tie-in during selector change-over.

Electrical Parameters
  • Type: M TYPE

  • Current Ratings:

    • Three-pole: 350 A, 500 A, 600 A, 700 A*

    • Single-pole: 350 A, 500 A, 600 A, 800 A, 1200 A, 1500 A, 1800 A, 2100 A*, 2400 A*

  • Voltage Levels: Available at 72.5 kV, 123 kV, 170 kV, 245 kV, and 300 kV

  • Vector Group Options: Compatible with both Y (Star) and D (Delta)

  • BIL (kV/kVp):

    • 140/350 (for 72.5 kV)

    • 230/550 (for 123 kV)

    • 325/750 (for 170 kV)

    • 395/950 (for 245 kV)

    • 460/1050 (for 300 kV)

  • Maximum Rated Step Voltage: 3300 Volts

  • Maximum Tap Positions:

    • Linear configuration: up to 22 positions

    • Pre-selector configuration: up to 35 positions

 

V Type On Load Tap Changer

Request Callback

Get Latest Price

TypeOn Load
PhaseThree Phase
Current500A
Voltage1500 V
Max Rated Switching Capacity525 kVA
Max Voltage123 kV
Operating Positions27 max (With Change Over Selector)
Key Features
  • The current rating is up to 500 A, with special designs available for 250 A and 400 A upon request.

  • The voltage rating supports up to 132 kV in Y (star) and D (delta) configurations.

  • The OLTC is suitable for both star (Y) and delta (D) applications.

  • The step voltage is rated at 1500 Volts.

  • The design includes an in-built selector switch for streamlined operation.

  • The unit supports bi-directional power flow, enhancing operational flexibility.

  • A compact dimensional arrangement helps save space in transformer designs.

  • The diverter switch inserts are easily removable, making the unit maintenance-friendly.

  • The OLTC supports a linear tap range of up to 14 positions, with some designs extending to 18.

  • A pre-selector arrangement allows up to 27 operating positions.

  • The design eliminates barrier board problems, simplifying installation and use.

Electrical Parameters
  • Type: V TYPE

  • Current Rating includes:

    • Three Pole options: 200 A, 350 A, and 500 A

    • Single Pole options: 350 A and 700 A* (optional/special design)

  • Voltage Levels available are: 40 kV, 76 kV, and 123/76 kV.

  • Vector configurations supported include both Y (star) and D (delta).

  • BIL (Basic Insulation Level) ratings include:

    • 70/200 kV

    • 140/350 kV

    • 230/550 kV

  • The maximum rated step voltage is 1500 Volts.

  • The maximum number of operating positions is:

    • 14 or 18 for linear operation

    • 27 for pre-selector operation

D Type On Load Tap Changer

Request Callback

Get Latest Price

PhaseThree Phase
3 Pole Current Rating500 Amps
ApplicationStar & Delta Applicaiton
Linear Positions18
Transformer TypeCurrent Transformer
Voltage2500 V
1 Pole Current Rating1500 Amps
Power220 kv
Pre Selector Position35
Key Features
  • The D Type Tap Changer has a proven track record since 1975 and is extensively used in network and furnace applications.

  • It supports currents up to 500 A in three-pole configurations and up to 1500 A* in single-pole configurations.

  • A special design is also available for 300 A applications.

  • It is compatible with both star (Y) and delta (D) winding connections.

  • The system supports voltage classes up to 220 kV, with a step voltage rating of up to 2500 Volts.

  • Models are available with separate diverter and selector assemblies for flexible installation.

  • The linear configuration supports up to 18 tap positions, while pre-selector arrangements allow up to 35 positions.

  • It is designed for bi-directional power flow, making it ideal for ultra heavy-duty applications.

  • Over 1500 in-tank installations are operating globally, many performing up to 500 operations per day.

Electrical Parameters
  • Type: D TYPE

  • Current Ratings:

    • Three-pole: 200 A, 400 A, 500 A

    • Single-pole: 200 A, 400 A, 600 A*, 800 A*, 1200 A*, 1500 A*

  • Voltage Levels: 36 kV, 60 kV, 110 kV, 150 kV

  • Vector Options: Y (Star), D (Delta)

  • BIL Ratings (kV/kVp):

    • 75/200 (36 kV)

    • 140/350 (60 kV)

    • 230/550 (110 kV)

    • 325/750 (150 kV)

  • Maximum Rated Step Voltage: 2500 Volts

  • Maximum Operating Positions:

    • Linear configuration: up to 18 positions

    • Pre-selector configuration: up to 35 positions

Dry Type On Load Tap Changer

Request Callback

Get Latest Price

PhaseThree Phase
Max Rated Through Current170A
Max Rated Step Voltage150V
Max Rated Switching Capacity75 kVA
Max Voltage For Operational Equipment Um11.5kV
Operating Positions Linear9 (Max)
Features – Dry Type On Load Tap Changer
  • Higher number of operations compared to conventional oil-type tap changers.

  • Simplified handling for easier installation and maintenance.

  • Comes with an integrated voltage regulator and motor-drive unit.

  • Encapsulated moving parts for enhanced safety and protection against accidental contact.

Heavy Duty On Load Tap Changer

Request Callback

Get Latest Price

TypeOn Load
PhaseThree Phase
Rated Voltage2500V
Frequency50 Hz
Power Rating1500A
Voltage For Operational Equipment150 kV
Operating Positions With Change Over Selector35 (Max)
Operating Positions Without Change Over Selector18 (Max)
Heavy Duty On Load Tap Changer – Key Features
  • Designed for High Performance: Engineered for demanding transformer applications with heavy-duty switching capability.

  • Wide Phase Compatibility: Suitable for both Single Phase and Three Phase systems.

  • Robust Power Handling: Supports a power rating range from 200 A to 1500 A, ideal for medium to high-capacity loads.

  • Reliable Operation: Built to operate efficiently at 2500 V and 50 Hz, ensuring consistent performance.

  • Durable Construction: Made to withstand harsh electrical environments with long service life and minimal maintenance.

  • On Load Switching: Enables voltage regulation under load, ensuring uninterrupted power delivery during tap change operations.

X

Contact Us

SATHYANARAYANAN.S (SENIOR MANAGER MARKETING)
EMR Tap Changers Private Limited
No. 612, 232, CTH Road, Thiruninravur
Tiruninravur Rs, Tiruvallur - 602024, Tamil Nadu, India

Get Directions
Send Email
Share: